Height-adjustable heavy-duty cassette for tube body RKFRSL, nominal size R9, stainless steel

Trench Part No. RKFR2 9 SL2V2 20
|
OBO Item No. 7409470
|
EAN 4012195869764
Trench Part No.
OBO Item No.
Floor height, max.
Floor height, min.
Floor covering thickness
Dimension h

Smallest selling unit: 1 piece

piece

Description

Round heavy-duty cassette for tube body of nominal size R9 for the installation of accessories in trunking systems, raised and cavity floors, in dry or wet-cleaned floors. Load class 2 to 20 kN.


Height-adjustable heavy-duty cassette with tube body with a load bearing capacity of 2-20 kN, 3-compartment. 3 APMT5 cover plates can be installed. For the installation of three UT4 universal supports for nine single accessories with support ring/support clamp or 12 Modul 45 devices. The tube body is not contained in the scope of delivery.
Height-adjustable round cassette, 3-compartment, of nominal size 9, for tube bodies. For the installation in trunking systems and in raised and cavity floors in dry- or wet-cleanded floors in indoor areas. Load class 2 to 20 kN. Three cover plates APMT5 can be installed.

Technical data

Technical data

Floor height, max.155 mm
Floor height, min.110 mm
Floor covering thickness20 mm
Height-adjustment range, max.155 mm
Height-adjustment range, min.110 mm
Number of installable devices12
Decouplableno
Installation diameter305
Suitable for cavity floor installationyes
Suitable for raised floor installationyes
Floor careWet
Number of mounting boxes3
Installation depth110 mm
Cable outlet versionLowerable tube body
Number of cable outlets1
Device support to accept mounting boxesyes
Protection rating IK codeIK10
Heavy load class20 kN (OBO SL2)
Installation system typeUT4
Heavy-duty versionyes
Nominal size for device installation unitsR9
Protection rating (IP) when usedIP20
Protection rating (IP) when unusedIP44
Version forRound
DimensionØ305mm
MaterialStainless steel 1.4301

Dimensions

Dimension h110 mm

Environmental Data

24,6974 kg CO2e / 1 PieceCO2 Footprint (GWP) Cradle-to-Gate
CO2 Footprint (GWP) Cradle-to-Gate24,6974 kg CO2e / 1 Piece

Downloads

0 selected

Data sheet (2)
Catalogues & Flyers (2)
Declarations (1)
Certificates (1)
Instructions and Aid (3)
Product images (2)
3D data downloads (1)
Tender specifications (1)

Variants

Floor height, max.
Floor height, min.
Floor covering thickness
Dimension h
RKFR2 9 SL2V2 20
OBO Item No.
7409470
Floor height, max.
155
Floor height, min.
110
Floor covering thickness
20
Nominal size for device installation units
R9
Dimension h
110
RKFR2 9 SL2V2 25
OBO Item No.
7409472
Floor height, max.
159
Floor height, min.
114
Floor covering thickness
25
Nominal size for device installation units
R9
Dimension h
114