Trunking unit, blank, locking, height 40−70 mm
Trench Part No. OKA-W2004030R
|OBO Item No. 7424460
|EAN 4012195244356



Trench Part No.
OBO Item No.
Length
Width
Duct height, min.
Trunking height, max.
Smallest selling unit: 2.4 m
2.4m
m
Description
Ready-to-mount trunking unit with three self-locking blanking covers for cable laying, consisting of the trunking base (floor trough with side and floor covering guide profiles) and trunking lid. Floor trough with holding shackles for self-contacting mounting of dividers. The scope of supply contains six height-adjustable wall fixing brackets, six screed anchors and three cover joint supports (for nominal trunking widths 200 and 300) or three height-adjustable cover joint supports (for nominal trunking widths 400, 500 and 600). Trunking lid screwed down when delivered.
Technical data
Dimensions
| Length | 2.400 mm |
|---|---|
| Width | 200 mm |
Technical data
| Number of compartments | 2 St. |
|---|---|
| Number of insertable partitions | 1 |
| Covers | 3 |
| Height-adjustment range, min. | 40 mm |
| Height-adjustment range, max. | 70 mm |
| Minimum screed height | 40 |
| Installation opening for on-floor tank | no |
| Seal installation option | yes |
| Decouplable | no |
| Floor plate | yes |
| With equipotential bonding | no |
| Removable cover | yes |
| Cover fastening, locking | yes |
| Mounting opening cover | no |
| Number of planned flush-mount units | 3 |
| With separating retainer | no |
| Cover material thickness | 4 |
| Suitable for expansion joint | no |
| With overhang | yes |
| With connection opening | no |
| Mounting opening | Without |
| ROHS-conformant | yes |
| Duct height, min. | 40 mm |
| Trunking height, max. | 70 mm |
| Dimension | 2400x200x40 |
| Surface | Strip galvanised |
| Material | Steel |
| Separating retainer fastening | Plug |
| Product series | OKA Series |
Environmental Data
50,0738 kg CO2e / 1 MeterCO2 Footprint (GWP) Cradle-to-Gate
| CO2 Footprint (GWP) Cradle-to-Gate | 50,0738 kg CO2e / 1 Meter |
|---|---|
| CO₂ Footprint (GWP) | 500738 kg CO₂e |
| Determination date of CO2 value | 2025-05-14T00:00:00.000+0200 |
| Declared Unit | Metres |
| Declared Unit Quantity | 1 |
Downloads
0 selected
Data sheet (1)
Declarations (3)
Product images (2)
3D data downloads (2)
Tender specifications (1)
Variants
Trench Part No.
Length
Width
Covers
Duct height, min.
Trunking height, max.
OBO Item No.
OKA-W2004030R
2.400
200
3
40
70
7424460
OKA-W3004030R
2.400
300
3
40
70
7424462
OKA-W4004030R
2.400
400
3
40
70
7424464
Width
OKA-W2004030R
OBO Item No.
7424460
Length
2.400
Width
200
Covers
3
Duct height, min.
40
Trunking height, max.
70
OKA-W3004030R
OBO Item No.
7424462
Length
2.400
Width
300
Covers
3
Duct height, min.
40
Trunking height, max.
70
OKA-W4004030R
OBO Item No.
7424464
Length
2.400
Width
400
Covers
3
Duct height, min.
40
Trunking height, max.
70